page_banner

Inverter Darurat Mini 184600/184603 V2

Katrangan singkat:

184600 Mini Emergency Inverter 36W, 184603 Mini Emergency Inverter 27W, Output AC sinusoidal murni.Inverter nggunakake Power Share Technology (PST) sing ngidini luminair sing dikontrol 0-10 Vdc siji utawa pirang-pirang kanthi otomatis nyetel lan nuduhake daya darurat.

  • 01
  • 04
  • 03

Fitur

Karakteristik

Ukuran Model

Wiring Diagram

Operasi / Testing / Maintenance

Pandhuan Safety

Tag produk

XVWQ1

1. Output AC sinusoidal murni.

2. Inverter nggunakake Power Share Technology (PST) sing ngidini luminair sing dikontrol siji utawa pirang-pirang 0-10 Vdc kanthi otomatis nyetel lan nuduhake daya darurat.

3. Output voltase setelan otomatis miturut voltase input beda.

4. Tes Otomatis.

5. omah aluminium banget slim lan bobot entheng.

6. Cocog kanggo aplikasi njero ruangan, garing lan lembab.


  • Sadurunge:
  • Sabanjure:

  • Jinis 184600 184603
    Jinis lampu Lampu LED, neon utawa pijar, tabung lan lampu
    voltase dirating 120-277VAC 50/60Hz
    Rated saiki 0.1A
    daya dirating 7W
    Faktor Daya 0,5-0,9 anjog, 0,5-0,9 lagging
    Tegangan output 120-277VAC 50/60Hz
    daya output 36W 27W
    Maks.daya saka0-10V dimming beban 180W 110W
    Baterei Li-ion
    wektu ngisi daya 24 Jam
    wektu discharge 90 menit
    Ngisi daya saiki 0.34A (maks.)
    Wektu urip modul 5 taun
    Siklus ngisi daya > 1000
    Suhu operasi 0-50(32°F-122°F)
    Efisiensi 80%
    Proteksi abnormal Swara voltase, liwat saiki, Inrush watesan saiki, liwat suhu, short circuit, mbukak sirkuit
    Kawat 18AWG/0.75 mm2
    EMC/FCC/IC standar EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, FCC part 15, ICES-005
    Standar safety EN 61347-1, EN 61347-2-7, UL924, CSA C.22.2 No. 141
    Meas.mm [inci] L346 [13.62]xW82 [3.23]xH30 [1.18] Pusat pemasangan: 338 [13.31]

    184600/184603

    BFDWQF

    Item No.

    Lmm [inci]

    Mmm [inci]

    Wmm [inci]

    Hmm [inci]

    184600

    346[13.62]

    338 [13.31]

    82 [3.23]

    30 [1.18]

    184603

    346[13.62]

    338 [13.31]

    82 [3.23]

    30 [1.18]

    Unit ukuran: mm
    Toleransi: ± 1 [0,04]

    184600

    XXX1

    XXX2

    184603

    AAA1

    AAA2

    OPERASI

    184600
    Nalika daya AC ditrapake, saklar tes LED dipadhangi, nuduhake yen baterei wis diisi.Nalika daya AC gagal, 184600 kanthi otomatis ngalih menyang daya darurat, operasi beban cahya ing kira-kira 20% (Reprogrammed kanggo 30%) saka daya luminer dirating (maks. 180W (PST @ 2 Vdc) utawa 120W (PST @ 3 Vdc) nggunakake Teknologi Power Share. 184600 uga bisa digunakake minangka inverter 36W mandiri nalika digunakake kanthi cahya cahya kurang saka utawa padha karo 36 watt. Nalika gagal daya, indikator switch test LED bakal mati. Nalika daya dipulihake, 184600 bali maneh. menyang mode operasi normal lan nerusake ngisi daya baterei. Wektu operasi darurat minimal 90 menit. Wektu pangisian daya kanggo discharge lengkap yaiku 24 jam.

    184603
    Nalika daya AC ditrapake, saklar tes LED dipadhangi, nuduhake yen baterei wis diisi.Nalika daya AC gagal, 184603 kanthi otomatis ngalih menyang daya darurat, operasi beban cahya ing kira-kira 20% (Reprogrammed kanggo 30%) saka daya luminer dirating (maks. 110W (PST @ 2 Vdc) utawa 80W (PST @ 3 Vdc) nggunakake Power Share Technology. 184603 uga bisa digunakake minangka inverter 27W mandiri nalika digunakake kanthi cahya cahya kurang saka utawa padha karo watt 27. Nalika gagal daya, indikator switch test LED bakal mati. Nalika daya dipulihake, 184603 bali maneh. menyang mode operasi normal lan nerusake ngisi daya baterei. Wektu operasi darurat minimal 90 menit. Wektu pangisian daya kanggo discharge lengkap yaiku 24 jam.

    TESTING lan Maintenance
    Tes Periodik ing ngisor iki dianjurake kanggo mesthekake yen sistem bisa digunakake kanthi bener.
    1. Priksa saklar tes LED (LTS) kanthi visual saben wulan.Sampeyan kudu madhangi nalika daya AC ditrapake.
    2. Nindakake tes discharge 30 detik kanthi mateni pemutus darurat saben wulan.LTS bakal mati.
    3. Nindakake tes discharge 90 menit sapisan saben taun.LTS bakal mati sajrone tes.

    UJI OTOMATIS
    1. Test Otomatis dhisikan: Nalika sistem disambungake kanthi bener lan powered on, 184600/184603 bakal nindakake Auto Test dhisikan.Yen ana kahanan ora normal, LTS bakal kerlip kanthi cepet*.Sawise kondisi ora normal didandani, LTS bakal bisa digunakake kanthi bener.
    2. Test otomatis saben wulan: 184600/184603 bakal nganakake tes otomatis saben wulan sawise 24 jam lan nganti 7 dina sawise wiwitan wiwitan.Banjur tes saben wulan bakal dileksanakake saben 30 dina, lan bakal nguji fungsi transfer saka normal menyang darurat, fungsi darurat, kahanan ngisi daya lan mbuwang.Wektu tes saben wulan kira-kira 30 detik.
    3. Tes Otomatis Tahunan: Iku bakal kelakon saben 52 minggu sawise wiwitan 24 jam pangisian daya lengkap, lan bakal nyoba voltase baterei dhisikan tepat, operasi darurat 90 menit, lan voltase baterei ditrima ing mburi test lengkap 90 menit.
    *Yen Tes Otomatis diganggu amarga mati daya, Tes Otomatis 90 menit lengkap bakal ditindakake maneh 24 jam sawise daya dipulihake.Yen gagal daya nyebabake baterei kosong, produk bakal miwiti maneh Tes Otomatis Awal, Tes Otomatis Saben wulan lan Taunan.

    TES MANUAL
    1. Pencet LTS kaping 2 terus-terusan sajrone 3 detik kanggo meksa tes saben wulan 30 detik.Sawise tes rampung, ing
    sabanjuré (30 dina) test saben wulan bakal count saka tanggal iki.
    2. Pencet LTS kaping 3 terus-terusan sajrone 3 detik kanggo meksa tes taunan 90 menit.Sawise tes rampung, ing
    sabanjuré (52-minggu) test taunan bakal count saka tanggal iki.
    3. Sajrone tes manual, penet terus LTS luwih saka 3 detik kanggo mungkasi tes manual.Wektu Tes Otomatis Jadwal sing wis diprogram ora bakal owah.

    KONDISI LED TEST SWITCH (LTS).

    Syarat LTS

    Default 2 VDC

    Bisa dipilih 3 VDC

    Alon kedip-kedip

    -

    Pengisian Normal

    On

    -

    Baterei Kebak

    Long ON, Short OFF, Long ON

    Ngisi daya normal lan

    Baterei Kebak

    -

    Mati

    Gagal daya

    Owah-owahan bertahap

    Mode Testing

    Cepet Blinking

    Kahanan Abnormal - Tindakan Korektif Dibutuhake

    TEKNOLOGI BAGIAN DAYA

    184600
    184600 nggunakke Power Share Technology (PST) sing ngidini siji utawa sawetara 0-10 Vdc kontrol luminer (nganti 180W gabungan daya luminer normal) kanggo otomatis nyetel lan nuduhake nganti 36W daya AC darurat.Sajrone operasi normal, inverter darurat bakal ngliwati voltase dimming normal (0-10 Vdc) ing timbal output surem, nanging banjur nyedhiyakake standar 2 VDC (utawa bisa dipilih **3 VDC) sajrone operasi darurat kanggo entuk kira-kira 20% (utawa bisa dipilih ** 30%) daya luminaire dirating nalika gagal daya darurat.
    ** Mode output suda 3 VDC (~30%) bisa dipilih lan gampang diprogram liwat switch test LED (LTS) kanthi menet tombol sing dipadhangi 5 detik, ngeculake, banjur mbaleni push tombol 5 detik (yaiku loro 5- tombol ditambahi kapindho nyurung ing wektu 13 detik).Kondisi lampu kilat LTS ngonfirmasi mode 3 VDC: Slow Blinking utawa ON.(Bali menyang standar 2 mode VDC kanthi mbaleni urutan penet tombol lengkap ing ndhuwur).
    Conto (standar 2 Vdc setelan): Four 45W LED luminaire (180W) bakal nuduhake 9W saben total 36W daya darurat saben 184600. 45W x 20% dim = 9W * 4 luminaires = 36W.Yen daya luminer luwih saka 45W, banjur 3 utawa kurang luminer bisa dioperasikake.
    Conto (3 setelan Vdc): Telung 40W LED luminaire (120W) bakal nuduhake 12W saben maksimum kasedhiya 36W daya darurat saben 184600. 40W x 30% dim = 12W.Kajaba iku, yen saben luminaire 30W, banjur 4 unit bisa 9W saben;dene yen daya luminer luwih saka 40W, banjur 2 utawa kurang luminer bisa dilakokno.

    184603
    184603 nggunakke Power Share Technology (PST) sing ngidini siji utawa sawetara 0-10 Vdc kontrol luminer (nganti 110W gabungan daya luminer normal) kanggo otomatis nyetel lan nuduhake nganti 27W daya AC darurat.Sajrone operasi normal, inverter darurat bakal ngliwati voltase dimming normal (0-10 Vdc) ing timbal output surem, nanging banjur nyedhiyakake standar 2 VDC (utawa bisa dipilih **3 VDC) sajrone operasi darurat kanggo entuk kira-kira 20% (utawa dipilih ** 30%) saka daya luminaire dirating sak Gagal daya.
    ** Mode output suda 3 VDC (~30%) bisa dipilih lan gampang diprogram liwat switch test LED (LTS) kanthi menet tombol sing dipadhangi 5 detik, ngeculake, banjur mbaleni push tombol 5 detik (yaiku loro 5- tombol ditambahi kapindho nyurung ing wektu 13 detik).Kondisi lampu kilat LTS ngonfirmasi mode 3 VDC: Slow Blinking utawa ON.(Bali menyang standar 2 mode VDC kanthi mbaleni urutan penet tombol lengkap ing ndhuwur).
    Conto (standar 2 Vdc setelan): Loro 50W LED luminaire (100W) bakal nuduhake 10W saben total 20W daya darurat saben 184603. 50W x 20% dim = 10W * 2 luminaires = 20W.
    Conto (3 setelan Vdc): Loro 40W LED luminaire (80W) bakal nuduhake 12W saben.40W x 30% = 12W, * 2 luminiaire = total 24W kanggo 184603.

    1. Kanggo nyegah kejut listrik, mateni sumber daya utama nganti instalasi rampung lan daya input AC diwenehake kanggo produk iki.

    2. Produk iki mbutuhake sumber daya AC un-switched 120-277V, 50/60Hz.

    3. Priksa manawa kabeh sambungan sesuai karo kode Listrik Nasional utawa Kanada lan peraturan lokal.

    4. Kanggo nyuda resiko kejut listrik, pedhot daya normal, sumber daya darurat lan konektor unit produk iki sadurunge servis.

    5. Kanggo operasi darurat LED, pijar, lampu neon lan meneng-base lamps.

    6. Gunakake produk iki ing 0 ° C minimal, 50 ° C suhu lingkungan maksimum (Ta).Bisa nyedhiyakake katerangan minimal 90 menit ing mode darurat.

    7. Produk iki cocok kanggo digunakake ing panggonan garing utawa lembab.Aja nggunakake njobo.Aja dipasang ing cedhak gas, pemanas, outlet udara utawa lokasi sing mbebayani liyane.

    8. Aja nyoba kanggo layanan baterei.A nutup, baterei non-pangopènan digunakake sing ora lapangan replaceable.Hubungi pabrikan kanggo informasi utawa layanan.

    9. Amarga produk iki ngandhut baterei, mangga manawa kanggo nyimpen ing lingkungan njero ruangan -20 ° C ~ 30 ° C.Iki kudu diisi daya lan dibuwang saben 6 sasi wiwit tanggal tuku nganti digunakake kanthi resmi, banjur diisi ulang 30-50% lan disimpen nganti 6 wulan liyane, lan liya-liyane.Yen baterei ora digunakake luwih saka 6 sasi, iku bisa njalari kakehan poto-discharge baterei, lan abang asil saka kapasitas baterei ora bisa dibalèkaké.Kanggo produk karo baterei kapisah lan modul darurat, mangga copot sambungan antarane baterei lan modul kanggo panyimpenan.Amarga sifat-sifat kimia, kahanan normal kanggo kapasitas baterei mudhun kanthi alami nalika digunakake.Pangguna kudu njupuk iki nalika milih produk.

    10. Panggunaan peralatan aksesoris sing ora dianjurake dening pabrikan bisa nyebabake kondisi sing ora aman lan garansi ora sah.

    11. Aja nggunakake prodhuk iki kanggo nggunakake liyane saka dimaksudaké.

    12. Instalasi lan layanan kudu dileksanakake dening personel layanan qualified.

    13. Produk iki kudu dipasang ing lokasi lan ing dhuwur sing ora bakal gampang kena gangguan dening personel sing ora sah.

    14. Priksa kompatibilitas produk sadurunge instalasi pungkasan.Priksa manawa polaritas bener nalika nyambungake baterei.Wiring kudu strictly sesuai karo diagram wiring, kasalahan wiring bakal ngrusak produk.Kasus kacilakan safety utawa kegagalan produk sing disebabake operasi ilegal pangguna ora kalebu ing lingkup panriman keluhan pelanggan, ganti rugi utawa jaminan kualitas produk.